Simulated Environmental Xenon Wearhering Solar Radiation Climatic Chamber / Climatic Test MachineProduct Description:The xenon arc lamp simulates the whole sunlight spectrum to reproduce the destructive light waves in different environments. Equipped with the appropriate filter atmosphere arc lamp t......
| Studio size (mm) | 750*500*600mm |
| External size (mm) | 1350*1200*1750mm (W*D*H) |
| Temperature range | normal temperature ~80ºC |
| Humidity range | light cycle 45% ~ 95% R.H, dark cycle 30% ~ 95% adjustable |
| Experimental blackboard temperature | adjustable from 45ºC to 100ºC (deviation ±3ºC) |
| Temperature fluctuation | ≤±0.5ºC |
| Temperature uniformity | ≤±2.0ºC |
| Humidity fluctuation | ≤±2% |
| Glass filter | borosilicate glass |
| Xenon light source | imported air-cooled xenon arc light source |
| Xenon lamp power | 2.5kw, xenon lamp power :2.5kw ×3 = 5.4kw, life :1200 hours |
| Rainfall time | 1 ~ 9999 minutes, continuous rainfall adjustable |
| Rainfall cycle | 1 ~ 240 minutes, interval (off) rainfall adjustable |
| Water spray nozzle aperture | Ф 0.8 mm (return hose ultra-fine filters to prevent the nozzle blocking) |
| Spraying period (spraying time/no spraying time) | 18min/102min or 12min/48min(spraying time/no spraying time) spraying pressure0.12 ~ 0.15 Mpa |
| Water pressure | 0.12 ~ 0.15kpa |
| Sample rack | sample tray size :75*300mm |
| Continuous adjustable time of illumination cycle | 1 ~ 999 hours |
| Xenon lamp spectral wavelength | 290nm ~ 800nm adjustable, irradiation range: 500W ~ 1200W/m2(adjustable). |
| Distance from the arc center to the sample | 250 ~ 300mm |
| Effective exposure area | 6400Cm2 |
| Heating power | 4.5kw |
| Humidifying power | 3KW |
| Standard | GB/ t1865-97 (2007), GB/ t9344-88, GB/ t16422.2-99, GB/ t2423.24-1995, ASTMG155, ISO10SB02/B04, SAEJ2527, SAEJ2412, etc |
| 1) Exterior material | SUS 201 double layer stainless steel plate |
| 2) Inner material | SUS 304 matt stainless steel plate |
| 3) Thermal insulation material | rigid polyurethane foam + high-efficient thermal insulation glass wool |
| 4) Sample frame | all stainless steel, samples fixed position adjustable, standard stamping forming sample |
| 5) Door | silicone rubber sealing device |
| (1) Refrigeration system and compressor 1. Refrigeration compressor: the original imported French "Taikang" fully enclosed refrigeration unit. 2. Cooling method: air cooling 3. Refrigerant: environmental protection refrigerant 4. Main refrigeration accessories: Japan "Arugong" solenoid valve; American "Emerson" drying filters, etc. Excellent quality of domestic and foreign well-known brands of air-cooled condenser and fin multi - section evaporator. |
| (2) Advantages of refrigeration system 1. Improved lubrication performance and lower piston temperature bring greater reliability; 2. Streamline body to improve airflow management; Reduced pressure, improved refrigeration efficiency; 3. Top unloading valve provides continuous minimum discharge line pulse; 4. SENTRONIC provides reliable lubrication protection system; 5. Use of environmentally friendly refrigerants R23, R404A (excluding CFCS) which are not prohibited by the Montreal convention or the amendment to London. |




PV Module Flame Test Equipment, UL 1703 , UL 790, IEC 61730
UL 1703 -2004 Falling Ball Impact Tester for PV Module
Solar Panels Testing Hail Impact Testing Machine IEC61646 IEC61215 Standard
Salt Spray Flowing Mixed Gas Corrosion Testing Machine
UL 1703 -2004 Standard Drop Ball Testing Machine
UL 1703 -2004 PV Module Durable Hot Spot Testing Machine